Re-marking of the 802.1p priority and DSCP priority
Packet filtering at Layer 2 to Layer 4, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, TCP/UDP port number, protocol type, and VLAN ID
Rate limiting in each queue and traffic shaping on interfaces
Security
Hierarchical user management and password protection
DoS attack defense, ARP attack defense, and ICMP attack defense
Binding of the IP address, MAC address, interface number, and VLAN ID
Port isolation, port security, and sticky MAC
MFF
Blackhole MAC address entries
Limit on the number of learned MAC addresses IEEE
802.1x authentication and limit on the number of users on an interface
AAA authentication, RADIUS authentication, HWTACACS+ authentication, and NAC
SSH V2.0
Hypertext Transfer Protocol Secure (HTTPS)
CPU defense
Blacklist and whitelist
Access Security
DHCP relay, DHCP server, DHCP snooping, and DHCP security
Lightning Protection
Service interface: 6 kV
Super Virtual Fabric (SVF)
Working as an SVF client that is plug-and-play with zero configuration
Automatically loading the system software package and patches of clients One-click and automatic delivery of service configurations
Supports independent running client
Management and Maintenance
iStack (excluding S5700-10P-LI-AC, S5700-10P-PWR-LI-AC, S5700S-28P-LI-AC, S5700S-52P-LI-AC and battery LAN switches)
Virtual Cable Test (VCT)
Remote configuration and maintenance using Telnet
SNMP v1/v2c/v3
RMON
eSight and web-based NMS
HTTPS
LLDP/LLDP-MED
System logs and multi-level alarms
802.3az EEE
Dying Gasp (excluding battery LAN switches)
Device hibernation mode (excluding PWR serials switches, battery LAN switches, S5700-10P-LI, S5700-28X-LI-24S, S5701-28X-LI-24S-AC and S5700-52X-LI-48CS-AC)
Interoperability
Supports VBST (Compatible with PVST/PVST+/RPVST)
Supports LNP (Similar to DTP)
Supports VCMP (Similar to VTP)
Operating Environment
Long-term operating temperature: 0°C to 50°C
Relative humidity: 5% to 95% (non-condensing)
Input Voltage
AC:
Rated voltage range: 100V to 240V, 50 Hz/60 Hz, Maximum voltage range: 90V to 264V, 47 Hz/63 Hz
Power Socket Position
rear power sockets
Battery
One slot for lead-acid battery charger module (supported by battery LAN switches)
Dimensions (W x D x H)
S5701-28TP-PWR-LI-AC: 442 mm x 310 mm x 43.6 mm
Power Consumption
S5701-28TP-PWR-LI-AC < 238.7W (PoE: 185W)
The?S5701-28TP-PWR-LI-AC gigabit enterprise switch is next-generation energy-saving switch developed by Huawei. With front power sockets, it ?can be installed in the 300 mm deep cabinet?and be maintained through the front panel, saving space in small equipment rooms, widely used in?various application?scenarios like?enterprise park access, convergence, gigabit access?of data center application scenarios.?Using?advanced energy conservation technology plus PoE function, the S5701-28TP-PWR-LI-AC is dedicated to?helping enterprise customers build a reliable and secure next-generation IT network.
Quick Specs
Figure 1 shows the appearance of Huawei?S5701-28TP-PWR-LI-AC.
?Table 1 shows the Quick Specs.
Product Code
S5701-28TP-PWR-LI-AC
Fixed Ports
24 x 10/100/1,000 Base-T Ethernet ports, 4 x GE SFP ports, 2 x Combo 10/100/1,000 Base-T Ethernet ports
MAC Address Table Size
16 MAC
Voltage Required
AC
Rated voltage range: 100V to 240V AC, 50/60 Hz
Maximum voltage range: 90V to 264V AC, 47/63 Hz
Power Device
AC power supply,?supporting RPS
Power?Consumption?Operational
Forwarding Performance
42?Mpps
Switching Capacity
256 Gbit/s?
Dimensions (W x D x H)
442 mm x 310 mm x 43.6 mm
Weight
5.6kg
Product Details
Figure 2 shows the front panel of Huawei?S5701-28TP-PWR-LI-AC.
?Note:
①
Twelve PoE+ 10/100/1000BASE-T ports
②
Twelve 10/100/1000BASE-T ports
③
Two 1000BASE-X ports
④
Two combo ports (10/100/1000BASE-T + 100/1000BASE-X)
⑤
One mini USB port
⑥
One console port
Figure 3 shows the back panel of Huawei?S5701-28TP-PWR-LI-AC.
?Note:
①
Ground screw
②
RPS socket
③
Jack for AC terminal locking latch
④
AC socket
*?The ground screw?is used with a?ground cable.
*RPS socket?is used with an?RPS cable, which is not hot swappable.?
A PoE switch can have an RPS power supply connected to this socket to provide inputs for system power supply and PoE power supply. The two inputs are independent of each other. The RPS power supply can also be used as a backup of the system power supply when it does not provide PoE power.
*The AC terminal locking latch is not delivered with the switch.
24 x 10/100/1,000 Base-T Ethernet ports, 2 Gig SFP and 2 dual-purpose 10/100/1,000 or SFP
12 x 10/100/1,000 Base-T Ethernet PoE+ ports, 12 x 10/100/1,000 Base-T Ethernet ports
?
Forwarding Performance
42?Mpps
42?Mpps
Switching Capacity
256 Gbit/s?
256 Gbit/s?
Power Supply
AC
AC?
PoE
Not supported
Supported
Power Consumption
Comparison between LI, SI, EI and HI
Huawei S5700 Series Enterprise Switches provides LI (Lite), SI (Standard), EI (Enhanced) and HI (Hyper) models for users. There are some differences among these four versions.
Choosing a selection results in a full page refresh.
Opens in a new window.
Cookie Consent Popup
We use cookies to enhance your browsing experience, serve personalized ads or content, and analyze our traffics. By clicking "Allow Cookies" you consent to our use of cookie.
×
Please wait...
Make An Offer
"S5701-28TP-PWR-LI-AC(12 Ethernet 10\/100\/1000 PoE+ ports,12 Ethernet 10\/100\/1000 ports,2 Gig SFP and 2 dual-purpose 10\/100\/1000 or SFP,AC) - S5701-28TP-PWR-LI-AC"
£0.00
"S5701-28TP-PWR-LI-AC(12 Ethernet 10\/100\/1000 PoE+ ports,12 Ethernet 10\/100\/1000 ports,2 Gig SFP and 2 dual-purpose 10\/100\/1000 or SFP,AC) - S5701-28TP-PWR-LI-AC"