CR5B0BKP0871 Specifications
|
| Basic Information |
| Part Number |
02350AFW |
| Model |
CR5B0BKP0871 |
| Description |
NE40E-X8A Integrated Chassis DC Components (Including 2 Fan Tray) |
| First Supported Version |
V800R008C20SPC100 |
| Technical Specifications |
| Chassis Height [U] |
21U |
| Weight Without Packaging (Full Configuration) [kg(lb)] |
[400G bundle] 188.1 kg (410.28 lb) [1T bundle] 209 kg (460.77 lb) |
| Weight Without Packaging [kg(lb)] |
78.9 kg (173.94 lb) |
| Maximum Power Consumption (With Configuration) [W] |
6080 W (fully loaded with LPUF-240s) 7110 W (fully loaded with LPUF-480s) 9500 W (fully loaded with LPUI-1Ts) |
| Typical Power Consumption (With Configuration) [W] |
4110 W (fully configured with LPUF-240s) 4770 W (fully configured with LPUF-480s) 6520 W (fully configured with LPUI-1Ts) |
| Typical Heat Dissipation (With Configuration) [BTU/hour] |
13334.8 BTU/hour (fully configured with LPUF-240s) 15473.8 BTU/hour (fully configured with LPUF-480s) 22155.3 BTU/hour (fully configured with LPUI-1Ts) |
| Power Supply Mode |
DC |
| Rated Input Voltage [V] |
-48 V ~ -60 V |
| Input Voltage Range [V] |
-40 V to -72 V |
| Maximum Input Current [A] |
63 A/single-module |
| Number of Service Board Slots |
8 |
| Number of Slots |
12 |
| Switching Capacity (bps, bit/s) |
25.16 Tbit/s (LPUI-1T) |
| Redundant Power Supply |
[400G bundle] 3+1 [1T bundle] 5+1 |
| Redundant Switch Fabrics |
3+1 |
| Redundant Fans |
[400G bundle] 2 assemblies in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F) [1T bundle] 3 assemblies in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F) |
| Redundant MPUs |
1:1 |
| Noise at Normal Temperature (Acoustic Power) [dB(A)] |
NEBS-compliance (< 78 dBA @ 27°C (80.8°F)) |
| Airflow Direction |
Front-to-back airflow |
| Maximum Number of Power Chassis Inputs |
8 channels/PEM*2 PEM=2 channels/PM*4 PEM=18 channels |
| Maximum Cable Input Size |
35 mm²/channel |
| Front-End Circuit Breaker/Fuse |
2 channels of 63 A/single-module [400G bundle] DC device: 4 PMs, with a total of 8 channels of 63 A [1T bundle] DC device: 6 PMs, with a total of 12 channels of 63 A |
| Storage Temperature [°C(°F)] |
-40°C to +70°C (-40°F to +158°F) |
| Restriction on the Operating Temperature Variation Rate [°C(°F)] |
< 0.5°C/min (32.9°F/min, non-condensing) |
| Short-Term Operating Temperature [°C(°F)] |
-5°C to +55°C (23°F to 131°F) |
| Long-Term Operating Temperature [°C(°F)] |
0°C to 45°C (32°F to 113°F) |
| Short-Term Operating Relative Humidity [RH] |
5% RH to 95% RH, non-condensing |
| Long-Term Operating Relative Humidity [RH] |
5% RH to 85% RH, non-condensing |
| Storage Relative Humidity [RH] |
5% RH to 95% RH, non-condensing |
| Long-Term Operating Altitude [m(ft.)] |
4000 m (13123.38 ft). From 1800 m to 4000 m (5905.51 ft to 13123.36 ft), the operating temperature of the device decreases by 1°C (1.8°F) for every 200 m (721.78 ft.) increase in altitude. |
| Storage Altitude [m(ft.)] |
< 5000 m (16404.2 ft.) |
| MTBF [year] |
22.32 |
| MTTR [hour] |
0.5 |